GAS POWER CYCLES 677
dharm
\M-therm\Th13-5.pm5
diagram as air heater. The air exhausted from the power turbine is cooled before readmission to
L.P. compressor. The various operations as indicated on T-s diagram (Fig. 13.51) are as follows :
Operation 1-2′ : Air is compressed from p 1 to px in the L.P. compressor.
Operation 2′-3 : Air is cooled in the intercooler at constant pressure px.
Work
Heat
exchanger
External
combustion
(Q ) 2
External
combustion
(Q ) 1
Q 4
10
1
Cooler
4 ′
L.P.
C
H.P.
C
H.P.
T
2 ′ 3
Intercooler
Q 3
5
6
7 ′
9 ′
8
L.P.
T
Fig. 13.50. Closed cycle gas turbine plant.
Operation 3-4′ : Air is compressed in the H.P. compressor from px to p 2.
Operation 4′-5 : High pressure air is heated at constant pressure by exhaust gases from
power turbine in the heat exchanger to T 5.
Operation 5-6 : High pressure air further heated at constant pressure to the maximum
temperature T 6 by an air heater (through external combustion).
Operation 6-7′ : The air is expanded in the H.P. turbine from p 2 to px producing work to
drive the compressor.
Operation 7′-8 : Exhaust air from the H.P. turbine is heated at constant pressure in the
air heater (through external combustion) to the maximum tempera-
ture T 8 (= T 6 ).
Operation 8-9′ : The air is expanded in the L.P. turbine from px to p 1 , producing energy
for a flow of work externally.
Operation 9′-10 : Air from L.P. turbine is passed to the heat exchanger where energy is
transferred to the air delivered from the H.P. compressor. The tem-
perature of air leaving the heat exchanger and entering the cooler is
T 10.