(Nora) #1
Measure axial clearance of 1 gear and 2 gear with thickness
gauge,
1 gear: 0.1—0.35mm
2 gear: 0.1—0.35mm

Measureradial clearance of 1 gear and 2 gear liking that shown
in figure, the maximal flop value is 0.056mm.

Take down tapered bearing liking that shown in figure
Note:


  1. Hold the lower end of shaft to prevent it falling.

  2. Clamp inner ring of bearing to make it reliable.


Disassemble tapered bearing on the other end with same
method.

1 gear 2 gear

Transmission—Disassemble assembly