Measure axial clearance of 1 gear and 2 gear with thickness
gauge,
1 gear: 0.1—0.35mm
2 gear: 0.1—0.35mmMeasureradial clearance of 1 gear and 2 gear liking that shown
in figure, the maximal flop value is 0.056mm.Take down tapered bearing liking that shown in figure
Note:- Hold the lower end of shaft to prevent it falling.
- Clamp inner ring of bearing to make it reliable.
Disassemble tapered bearing on the other end with same
method.1 gear 2 gearTransmission—Disassemble assembly176