目录.p65

(Nora) #1
Air conditioner--Refrigerant

zThe pressure of high and
low pressure end is high.
zThere is no bubble on
window when engine
speed decreases.

zToo much refrigerant in
system incurs this.
zHeat dispersion of con-
denser is bad.

(1)Clean the condenser.
(2)Check the function of
cooling fan.
(3)If those two items above
are normal, check the re-
frigerant quantity. Fill
applicable refrigerant.

zFilled refrigerant is too
much.
zHeat dispersion of con-
denser is bad¡ú¡ú¡ú¡ú¡úheat dis-
persion sheet of con-
denser is obstructed or fan
engine has malfunction.

Phenomenon Possible reason Diagnose Method

State: cooling degree is not enough.

zThe pressure of high and
low pressure end is high.
zPipeline of low pressure
end is too hot to contact.
zThere is bubble on
window.

Air enters cooling system. (1)Check whether the Re-
frigerant oil is too dirt or
lack.
(2)Take our vacuum and fill
new refrigerant.

zThere is air in cooling
system.
zIt does not take out
vacuum completely.

Phenomenon Possible reason Diagnose Method

State: cooling degree is not enough.

(6) Refrigerant is too much or the radiating fin of condenser is bad

(7) Air enters cooling system

Note: i f cooling system is
opened, and it does not
take out vacuum when
filling refrigerant, this
state will happen.

 218 

Free download pdf