目录.p65

(Nora) #1
Change..........................................................


  1. Reclaim HFC-134a (R134a)


(a) Turn A/C switch to ON.
(b) Keep the engine speed at 1000 rpm, and rotate cooling compressor for 5 to 6 minutes to make
refrigerant cycle, this could collect the Refrigerant oil in each part in cooling compressor as possible.
(c) Extinguish the engine.
(d) Drain the refrigerant.


  1. Fill refrigerant


(a) Use vacuum pump to take out vacuum.
(b) Fill the refrigerant HFC-134a (R134a)
Standard quantity: 660 ± 10g


  1. Heat the engine

  2. Check whether the refrigerant leaks.


Air conditioner--Refrigerant

 221 

Bubble
disappearing
point

Too much filling refrigerant

Increase 100g

Filling quantity of refrigerant

Pressure at
the high
pressure side

Refrigerant quantity
Auxiliary condenser system

Applicable
filling scope
Free download pdf