- Disassemble servo motor of air mixing flow choke
(automatic air conditioner).
Disassemble two screws and servo motor of air mixing flow
choke.
- Disassemble air conditioner pipeline.
(a) Disassemble two screws and extending cover.
(b) Use planetary wrench (5.0mm) to disassemble two plan-
etary bolts and air conditioner pipeline.
(c) Disassemble two O-shape loops from air conditioner
pipeline.
- Disassemble expansion valve.
(a) Disassemble expansion valve from air conditioner group.
(b) Disassemble two O-shape rings from air conditioner
pipeline.
- Disassemble No.1 air conditioning heat sensitive
resistance.
- Disassemble evaporator.
(a) Disassemble six screws and air conditioning group parts.
(b) Pull out evaporator.
- Disassemble central heating core.
Disconnect fixed claw and central heating water pipe defend-
ing cover, then pull out central heating core.
Air conditioner--Air conditioner central heating core assembly
Fixing
claw
231