Simulink Control Design™ - MathWorks

(Tuis.) #1
TipTo highlight any selected signal in the Simulink model, click. To remove a signal

from the input or output list, click. When you have selected multiple signals, you can

reorder them using and. For more information on how to specify signal locations
for a tuning goal, see “Specify Goals for Interactive Tuning” on page 10-39.

Desired Response


Use this section of the dialog box to specify the shape of the desired step response.


  • First-order characteristics


Specify the desired step response (the reference model Href) as a first-order response
with time constant τ:

Href=
1/τ
s+1/τ

.


Enter the desired value for τ in the Time Constant text box. Specify τ in the time
units of your model.


  • Second-order characteristics


Specify the desired step response as a second-order response with time constant τ,
and natural frequency 1/τ.

Enter the desired value for τ in the Time Constant text box. Specify τ in the time
units of your model.

Enter the target overshoot percentage in the Overshoot text box.

The second-order reference system has the form:

Href=
1/τ^2
s^2 +2ζ/τs+1/τ^2

.


The damping constant ζ is related to the overshoot percentage by ζ =
cos(atan2(pi,-log(overshoot/100))).


  • Custom reference model


10 Control System Tuning