Simulink Control Design™ - MathWorks

(Tuis.) #1

Option Name Option Value


'SettlingPeriods' Number of periods corresponding to the transient portion of
the simulated response at a specific frequency, before the
system reaches steady state, specified as either:



  • Scalar to set all frequencies to same value

  • Vector to set each frequencies to a different value


Before performing the estimation, frestimate discards this
number of periods from the output signals.

Default: 1

'ApplyFilteringInFRESTIMATE' Frequency-selective FIR filtering of the input signal before
estimating the frequency response using frestimate.



  • 'on' (default)

  • 'off'


For more information, see the frestimate algorithm.

frest.Sinestream