Simulink Control Design™ - MathWorks

(Tuis.) #1
Settings

Default:
[] for Pole-Zero Plot block
1 for Check Pole-Zero Characteristics block


  • Finite positive real scalar for one bound.

  • Cell array of finite positive real scalars for multiple bounds.


Tips


  • To assert that the settling time bounds are satisfied, select both Include settling
    time bound in assertion on page 16-262 and Enable assertion on page 16-277.

  • You can add or modify settling time bounds from the plot window:

    • To add a new settling time bound, right-click the plot, and select Bounds > New
      Bound. Specify the new value in Settling time.

    • To modify a settling time bound, drag the corresponding bound segment.
      Alternatively, right-click the bound and select Bounds > Edit. Specify the new
      value in Settling time (sec) <.




You must click Update Block before simulating the model.

Command-Line Information
Parameter: SettlingTime
Type: character vector
Value: [] | 1 | finite positive real scalar| cell array of finite positive
real scalars. Must be specified inside single quotes ('').
Default: '[]' for Pole-Zero Plot block, '1' for Check Pole-Zero Characteristics block.

See Also

Plot Linear Characteristics of Simulink Models During Simulation on page 2-82

“Verify Model at Default Simulation Snapshot Time” on page 14-6

Include percent overshoot bound in assertion


Check that the pole locations satisfy approximate second-order bounds on the percent
overshoot, specified in Percent overshoot <= on page 16-263. The software displays a
warning if the poles lie outside the region defined by the percent overshoot bound.

16 Blocks — Alphabetical List