Enter 10 in the From box.
Enter 100 in the To box.
Enter 10 in the box for the number of frequency points.
Click OK.
The added points are visible in the Frequency content viewer of the Create
sinestream input dialog box.
d In the Frequency content viewer of the Create sinestream input dialog box,
select all the frequency points.
e Specify input sinestream parameters.
Change the Number of periods and Settling periods to ensure that the model
reaches steady-state for each frequency point in the input sinestream.
Enter 30 in the Number of periods box.
Enter 25 in the Settling periods box.
f Create the input sinestream.
Click OK. The new input signal, in_sine1, appears in the Linear Analysis
Workspace.
Effects of Time-Varying Source Blocks on Frequency Response Estimation