Simulink Control Design™ - MathWorks

(Tuis.) #1

Validate Operating Point in Linear Analysis Tool


When you compute an operating point using Linear Analysis Tool, the software does not
highlight constraint violations. Instead, you must inspect the operating point report
information for any violations.

If you trim the model from the preceding Steady State Manager example using the
same specifications in the Linear Analysis Tool, the software creates an operating point
in the Data Browser, in the Linear Analysis Workspace.

To check whether the operating point satisfies the specified constraints, in the Data
Browser, in the Linear Analysis Workspace, double-click the operating point.

In the Edit dialog box, for the three steady-state specifications, the trimmed state values
in the Actual dx column violate the zero Desired dx values.

Validate Operating Point at the Command Line


When you compute an operating point at the command line, the findop function outputs
an operating point report to the Command Window by default. You can also return the
operating point report as an output argument. For more information, see findop. To

1 Steady-State Operating Points

Free download pdf