Microsoft Word - Cengel and Boles TOC _2-03-05_.doc

(ff) #1
below recommended levels can increase the energy use by as much as
25 percent.
6.Avoid excessive ice build-upon the interior surfaces of the evaporator.
The ice layer on the surface acts as insulation and slows down heat
transfer from the freezer section to the refrigerant. The refrigerator
should be defrosted by manually turning off the temperature control
switch when the ice thickness exceeds a few millimeters.
Defrosting is done automatically in no-frost refrigerators by
supplying heat to the evaporator by a 300-W to 1000-W resistance
heater or by hot refrigerant gas, periodically for short periods. The
water is then drained to a pan outside where it is evaporated using the
heat dissipated by the condenser. The no-frost evaporators are basically
finned tubes subjected to air flow circulated by a fan. Practically all the
frost collects on fins, which are the coldest surfaces, leaving the
exposed surfaces of the freezer section and the frozen food frost-free.
7.Use the power-saver switchthat controls the heating coils and prevents
condensation on the outside surfaces in humid environments. The low-
wattage heaters are used to raise the temperature of the outer surfaces
of the refrigerator at critical locations above the dew point in order to
avoid water droplets forming on the surfaces and sliding down.
Condensation is most likely to occur in summer in hot and humid
climates in homes without air-conditioning. The moisture formation on
the surfaces is undesirable since it may cause the painted finish of the
outer surface to deteriorate and it may wet the kitchen floor. About
10 percent of the total energy consumed by the refrigerator can be
saved by turning this heater off and keeping it off unless there is visible
condensation on the outer surfaces.
8.Do not block the air flow passagesto and from the condenser coils of
the refrigerator. The heat dissipated by the condenser to the air is
carried away by air that enters through the bottom and sides of the
refrigerator and leaves through the top. Any blockage of this natural
convection air circulation path by large objects such as several cereal
boxes on top of the refrigerator will degrade the performance of the
condenser and thus the refrigerator (Fig. 6–57).
These and other commonsense conservation measures will result in a
reduction in the energy and maintenance costs of a refrigerator as well as an
extended trouble-free life of the device.

314 | Thermodynamics


Cabinet

Refrigerator

Warm
air

Cool
air

Coils

FIGURE 6–57


The condenser coils of a refrigerator
must be cleaned periodically, and the
airflow passages must not be blocked
to maintain high performance.


EXAMPLE 6–8 Malfunction of a Refrigerator Light Switch

The interior lighting of refrigerators is provided by incandescent lamps whose
switches are actuated by the opening of the refrigerator door. Consider a
refrigerator whose 40-W lightbulb remains on continuously as a result of a
malfunction of the switch (Fig. 6–58). If the refrigerator has a coefficient of
performance of 1.3 and the cost of electricity is 8 cents per kWh, determine
the increase in the energy consumption of the refrigerator and its cost per
year if the switch is not fixed.

Light bulb
40 W

FIGURE 6–58


Schematic for Example 6–8.

Free download pdf