when the utilization factor is defined on the basis of the heating value of the
fuel. The utilization factor of the ideal steam-turbine cogeneration plant is
obviously 100 percent. Actual cogeneration plants have utilization factors as
high as 80 percent. Some recent cogeneration plants have even higher uti-
lization factors.
Notice that without the turbine, we would need to supply heat to the
steam in the boiler at a rate of only 100 kW instead of at 120 kW. The addi-
tional 20 kW of heat supplied is converted to work. Therefore, a cogenera-
tion power plant is equivalent to a process-heating plant combined with a
power plant that has a thermal efficiency of 100 percent.
The ideal steam-turbine cogeneration plant described above is not practi-
cal because it cannot adjust to the variations in power and process-heat
loads. The schematic of a more practical (but more complex) cogeneration
plant is shown in Fig. 10–22. Under normal operation, some steam is
extracted from the turbine at some predetermined intermediate pressure P 6.
The rest of the steam expands to the condenser pressure P 7 and is then
cooled at constant pressure. The heat rejected from the condenser represents
the waste heat for the cycle.
At times of high demand for process heat, all the steam is routed to the
process-heating units and none to the condenser (m

.
7 0). The waste heat is
zero in this mode. If this is not sufficient, some steam leaving the boiler is
throttled by an expansion or pressure-reducing valve (PRV) to the extraction
pressure P 6 and is directed to the process-heating unit. Maximum process
heating is realized when all the steam leaving the boiler passes through the
PRV (m

.
5 m

.
4 ). No power is produced in this mode. When there is no
demand for process heat, all the steam passes through the turbine and the
condenser (m

.
5 m

.
6 0), and the cogeneration plant operates as an ordi-
nary steam power plant. The rates of heat input, heat rejected, and process
heat supply as well as the power produced for this cogeneration plant can be
expressed as follows:

(10–25)

(10–26)

(10–27)

(10–28)

Under optimum conditions, a cogeneration plant simulates the ideal
cogeneration plant discussed earlier. That is, all the steam expands in the
turbine to the extraction pressure and continues to the process-heating unit.
No steam passes through the PRV or the condenser; thus, no waste heat is
rejected (m

.
4 m

.
6 and m

.
5 m

.
7 0). This condition may be difficult to
achieve in practice because of the constant variations in the process-heat
and power loads. But the plant should be designed so that the optimum
operating conditions are approximated most of the time.
The use of cogeneration dates to the beginning of this century when
power plants were integrated to a community to provide district heating,
that is, space, hot water, and process heating for residential and commercial
buildings. The district heating systems lost their popularity in the 1940s
owing to low fuel prices. However, the rapid rise in fuel prices in the 1970s
brought about renewed interest in district heating.

W

#
turb^1 m

#
4 m

#
521 h 4 h 62 m

#
71 h 6 h 72

Q

#
pm

#
5 h 5 m

#
6 h 6 m

#
8 h 8

Q

#
outm

#
71 h 7 h 12

Q

#
inm

#
31 h 4 h 32

580 | Thermodynamics


Pump I

Turbine

7

Boiler

Condenser

1

Pump II

Process
heater

Expansion
valve

3
8

4

(^56)
2
FIGURE 10–22
A cogeneration plant with adjustable
loads.