24 The measurement of temperature
At the end of this chapter you should be
able to:
- describe the construction, principle of
operation and practical applications of the
following temperature measuring devices:
(a) liquid-in-glass thermometer (includ-
ing advantages of mercury, and
sources of error)
(b) thermocouples (including advantages
and sources of error)
(c) resistance thermometer (including
limitations and advantages of plat-
inum coil)
(d) thermistors
(e) pyrometers (total radiation and opti-
cal types, including advantages and
disadvantages
- describe the principle of operation of
(a) temperature indicating paints and
crayons
(b) bimetallic thermometers
(c) mercury-in-steel thermometer
(d) gas thermometer
- select the appropriate temperature measur-
ing device for a particular application
24.1 Introduction
A change in temperature of a substance can often
result in a change in one or more of its physical
properties. Thus, although temperature cannot be
measured directly, its effects can be measured. Some
properties of substances used to determine changes
in temperature include changes in dimensions, elec-
trical resistance, state, type and volume of radiation
and colour.
Temperature measuring devices available are many
and varied. Those described in sections 24.2 to
24.10 are those most often used in science and
industry.
24.2 Liquid-in-glass thermometer
Aliquid-in-glass thermometeruses the expansion
of a liquid with increase in temperature as its prin-
ciple of operation.
Construction
A typical liquid-in-glass thermometer is shown in
Figure 24.1 and consists of a sealed stem of uniform
small-bore tubing, called a capillary tube, made of
glass, with a cylindrical glass bulb formed at one
end. The bulb and part of the stem are filled with a
liquid such as mercury or alcohol and the remaining
part of the tube is evacuated. A temperature scale
is formed by etching graduations on the stem. A
safety reservoir is usually provided, into which the
liquid can expand without bursting the glass if the
temperature is raised beyond the upper limit of the
scale.
0 102030405060708090100
Liquid
Bulb
Scale
Capillary tube
Safety
reservoir
Figure 24.1
Principle of operation
The operation of a liquid-in-glass thermometer
depends on the liquid expanding with increase
in temperature and contracting with decrease in