Section 8 - Wall Surfacing (Page 32 of 32)


COMPLIANCE


7 FABRICATED and INSTALLED (continued)


7.3 GAPS, FLUSHNESS, FLATNESS, and ALIGNMENT (continued)

7.3.4 The following is intended to provide examples of how and where compliance testing is measured:

D

B

C

A

B


F


F


E


E


Measured on the concave face


A - Gaps when surfaces are mitered or butted
B - Gaps when parallel pieces are joined
C - Gaps when edges are mitered or butted
D - Flushness between two surfaces
E - Flatness of panel product
F - Flushness of edgebanding
G - Chipout

G

8