215
© 2009, AWI, AWMAC, WI - Architectural Woodwork Standards - 1st Edition, October 1, 2009
As may be updated by errata at http://www.awinet.org, http://www.awmac.com, or http://www.woodworkinstitute.com/awserrata/
GENERAL
1.2 BASIC CONSIDERATIONS (continued)
1.2.18 At FLUSH doors (continued)
1.2.18.5 EXAMPLES (continued)
1.2.18.5.7 WOOD-VENEER FACE with hollow core (HC-7):
7 Ply
Rail
Stile
Core
Cross Band
Cross Band
HPDL or Veneer
1.2.18.6 PAIR MATCH is required; the example below is of book-matched, center-balance matched faces:
1.2.18.7 SET MATCH is required; the example below is of book-matched, center-balance matched faces:
Section 9 - Doors (Page 10 of 37)
9