AWS EDITION 1, 2009

(Tina Sui) #1

215


© 2009, AWI, AWMAC, WI - Architectural Woodwork Standards - 1st Edition, October 1, 2009


As may be updated by errata at http://www.awinet.org, http://www.awmac.com, or http://www.woodworkinstitute.com/awserrata/

GENERAL


1.2 BASIC CONSIDERATIONS (continued)
1.2.18 At FLUSH doors (continued)

1.2.18.5 EXAMPLES (continued)
1.2.18.5.7 WOOD-VENEER FACE with hollow core (HC-7):

7 Ply

Rail

Stile

Core

Cross Band

Cross Band

HPDL or Veneer

1.2.18.6 PAIR MATCH is required; the example below is of book-matched, center-balance matched faces:

1.2.18.7 SET MATCH is required; the example below is of book-matched, center-balance matched faces: