291
© 2009, AWI, AWMAC, WI - Architectural Woodwork Standards - 1st Edition, October 1, 2009
As may be updated by errata at http://www.awinet.org, http://www.awmac.com, or http://www.woodworkinstitute.com/awserrata/
EXECUTION
DESCRIPTION E C P
6.1
G E N E R A L
GENERAL (continued)
6.1.12
W A L L A N C H O R A G E
CASEWORK WALL ANCHORAGE, except for PENINSULA/ISLAND casework or base casework with
MECHANICAL SPACING ALLOWANCES (because of the need to be engineered on an individual basis),
requires:
6.1.12.1
CONTINUOUS BLOCKING or
BACKING of at least 2” x 6”
(51 mm x 152 mm) nominal
wood or 6” x 16 ga (152 mm x
1.2 mm) sheet metal, installed
by others, shall be appropriately
located in all wood or metal stud
walls.
2X6 flat blocking
by others
6" X 16 ga. cont.
sheet metal
stud by others
6.1.12.2
MANUFACTURER to provide
appropriate blocking or backing
location layouts on their shop
drawings for all tall, base, and
wall-hung casework for both top
and bottom runs of fasteners.
Storage
Cabinet
Wall Cabinet
Base Cabinet
6.1.12.3
ADJACENT cabinet units to be fastened together at the front with a minimum of two #8 x 1-1/4”
(31.7 mm) flat-, oval-, or pan-head screws, a maximum of 30” (762 mm) on center, and:
6.1.12.3.1 Binder-head SEX BOLTS are permitted.
6.1.12.3.2 If COVER CAPS are required, it shall be so specified. M
Section 10 - Casework (Page 48 of 51)