565
Appendix B
© 2009, AWI, AWMAC, WI - Architectural Woodwork Standards - 1st Edition, October 1, 2009
(Appendix B is not part of the AWS for compliance purposes)
9 - Wood Doors
Construction Details
General Moulding Requirements
Species shall match or be compatible with face veneer or
laminate.
Specify transparent or opaque finish.
Moulding shall be free of open defects, shake, splits, or doze.
M o u l d i n g m u s t b e s m o o t h a n d f r e e o f v i s i b l e k n i f e , s a w , o r s a n d i n g
marks. Specify from following options:
MEETING EDGE OPTIONS
No bevel Bevel
Flat astragal
Rabbeted
Metal edge guards
and astragal
Tee astragal
Parallel bevel
Double egress
Metal edge guards
TRANSOM MEETING EDGE OPTIONS
Non-rabbeted Rabbeted
Glazing Options
Flush Mouldings
Lip Moulding
Metal vision frame
W = Wood mouldings
M = Metal vision frames
All cutouts for metal or wood vision panels must be a minimum
of 6” (152 mm) from the edge of the door and/or other cutouts
for louvers, locks, closers, or other hardware for 45-minute
though 90-minute doors. 20-minute PC and SLC doors must be
a minimum of 5” (127 mm) [5”], and 20 minute SCLC doors must
be a minimum of 1-1/2” (38 mm).
These distances must be maintained or the fire label and warranty
will be voided.
Using a 10” (254 mm) margin between the edge of the door and
the edge of any cutout near the lock area will eliminate most label
and warranty conflicts.
B