Appendix G: Heat Loss Calculations
For the heat loss calculations, the formula 푄=푈퐴∆푇 where,
Q is the heat transfer rate in Btu per hour.
U is the heat transfer coefficient U-value= 1/R-value, measured in Btu/h (F) (ft^2 ).
A is the surface area in squared feet.
∆푇 is the temperature inside minus the temperature outside.
If the greenhouse is entirely covered with transparent panels the heat loss will be the followings.
Assuming the greenhouse is fully insulated on the walls that are not transparent.
Insulation
(R-value)
Heat loss (U-
value)
Btu/(h*F*ft^2 )
Area
(ft^2 )
∆푇
(60F-
15F)
Q
(Btu/h)
Solexx 2.10-2.30 0.45 1760 45 35640
Multi-wall
polycarbonate
1.5-2.0 0.6 1760 45 47520
Single-wall
polycarbonate
2.0 0.5 1760 45 39600
If the greenhouse has one wall made of plywood
Insulation
(R-value)
Heat loss (U-
value)
Btu/(h*F*ft^2 )
Area
(ft^2 )
∆푇
(60F-
15F)
Q
(Btu/h)
Solexx 2.10-2.30 0.45 1496 45 30294
Multi-wall
polycarbonate
1.5-2.0 0.6 1496 45 40392
Single-wall
polycarbonate