DHARM
646 GEOTECHNICAL ENGINEERING
Allowable soil pressures:
150 kN/m^2 for DL + reduced LL
225 kN/m^2 for DL + LL
Column loads
Column A Column B
DL 540 kN 690 kN
LL 400 kN 810 kN
Distance c/c of columns = 5.4 m
Projection of footing beyond column not to exceed 0.5 m.
Resultant Column Loads Column A Column B Total
DL + reduced LL 740 kN 1095 kN 1835 kN
DL + LL 940 kN 1500 kN 2440 kN
For uniform pressure under DL + reduced LL:
Let us use equal projections beyond columns A & B.
L′ = 5.4 m
L = L′ + 2e 1 = 5.4 + 2 × 0.5 = 6.4 m.
Total area required, A = 1835/150 = 12.23 m^2
x, distance of resultant column load from the left edge = 3.22 + 0.5 = 3.72
3.22 m 2.18 m
740 kN R = 1835 kN 1095 kN
L = 5.4 m¢
L = 6.4 m
0.5 m Section 0.5 m
3.7 m 2.7 m
Col. A Col. B
Plan
2440 kN
C.G.
e = 0.12 m
B = 1.05 m 2 B = 2.85 1
Fig. 15.32 Trapezoidal combined footing (Ex. 15.5)
∴ B 1 =^23121223
64
3372
64
A 1
L
x
L
F −
HG
I
KJ
= ××F −
HG
I
KJ
.
.
.
.
= 2.85 m
B 2 =^2 2 12 23
(^164)
A
L
−=B
×.
.
- 2.85 = 1.05 m