DHARMPILE FOUNDATIONS 691Qg = c′. Nc. Ag + c. Pg. L
Here, cohesion c = c′ = 45 kN/m^2
Nc is taken as 9.
L = 9 m B = 2s + d = 2 × 0.9 + 0.3 = 2.1 m
Pg = 4B = 8.4 m
Ag = B^2 = 2.1^2 m^2 = 4.41 m^2
Substituting,
Qg = 45 × 9 × 4.41 + 45 × 8.4 × 9
= 5,186 kN.
Individual pile failure:
Qg = n[qeb. Ab + fs. As]
= n[cNcAb + α. c. As]= 9 45 9×× × 4 032 +075 45× ×× ×03 9L
NMO
QPπ .. π.= 2,835 kN
In this case, individual pile failure governs the design. Allowable load on the pile group=2 835
25,
.≈ 1,130 kN.Example 16.6: Design a square pile group to carry 400 kN in clay with an unconfined com-
pression strength of 60 kN/m^2. The piles are 30 cm diameter and 6 m long. Adhesion factor
may be taken as 0.6.
Cohesion, c =60
2= 30 kN/m^2
Frictional resistance of one pile
= α. c. πd. L
= 0.6 × 30 × π × 0.3 × 6 = 101.8 kNSafe load per pile =101.8
3≈ 34 kN (with a factor of safety of 3)Approximate number of piles required =400
34≈ 12
Let us try a square 16-pile group with centre-to-centre spacing of 60 cm.Efficiency ηg = 1 –φ
9011
°L −+ −
NMO
QPmn nm
mn()( )φ = tan–1(d/s) = tan–1 (d/2d) = 26.565= 1 –26 565
904343
44. ×+×
×
L
NM
O
QP = 0.56
Safe load on the pile group = 0.56 × 16 × 34 ≈ 305 kN with a factor of safety of 3.It will be 400 kN with η =305 3
400×
= 2.3