Room Acoustics 861The complete formula for calculating the complete series of modes is as follows:
F
nx
Lxny
Lynz
Lz172
⎛^222
⎝
⎜⎜
⎜
⎞
⎠
⎟⎟
⎟⎟
⎛
⎝
⎜⎜
⎜⎜
⎞
⎠
⎟⎟
⎟⎟
⎛
⎝
⎜⎜
⎜
⎞
⎠
⎟⎟
⎟⎟
⎡
⎣
⎢⎢
⎢
⎢
⎤
⎦
⎥
⎥
⎥
1
2
.At low frequencies, the density of room modes is low, causing each to stand out and
consequently be more audible. However, at higher frequencies, the density becomes very
much greater, forming a continuous spectrum, that is, at any given frequency, a number
of modes will occur, which counteract each other. Room modes therefore generally cause
problems at low or lower midfrequencies (typically up to 250–500 Hz). While this is
primarily due to the low modal density at these frequencies, it is also exacerbated by the
general lack of sound absorption that occurs at low frequencies in most rooms.
After determining that the room/studio dimensions are appropriate to ensure low
coincidence of modal frequencies, control of room modes is brought about by providing
appropriate absorption to damp down the resonances.
29.3.3 Absorber Performance
Sound absorbers effectively fall into four categories:
- High and mediumfrequency dissipative porous absorbers.
- Low-frequency panel or membrane absorbers.
5101520253035404510 20 30 40 50 60 70 80 90 100
Frequency (Hz)13.5
12
10.5
9
7.5
6
4.5
3MetersDistance between room surfaces (feet)Figure 29.9 : Axial mode frequency versus room dimension.