PILES AND PILING FORMULAS 111
whereBwidth of rectangular footing
Llength of rectangular footing
eeccentricity of loading
For the other case Fig. 4.2(c), the soil pressure ranges from 0 to a maximum of
qm^2 P (4.17)
3 L(B/2e)
TABLE 4.2 Shape Corrections for Bearing-Capacity Factors of Shallow
Foundations*
Correction factor
Shape of
foundation Nc Nq Ny
Rectangle†
Circle and
square
0.60
*After De Beer, E. E., as modified by Vesic, A. S. See Fang, H. Y., Foundation
Engineering Handbook, 2d ed., Van Nostrand Reinhold, New York.
†No correction factor is needed for long-strip foundations.
1 ^1 tan
Nq
Nc
1 0.4
B
L
1
B
L
1 tan
B
L
Nq
Nc
p
(b) (d)
(a) (c)
P
b
b
P M M
P P
P 1
p 2
e
e
b
3( – 2 e)
FIGURE 4.2 Footings subjected to overturning.