BUILDING AND STRUCTURES FORMULAS 209LOAD-AND-RESISTANCE FACTOR
DESIGN FOR BUILDING COLUMNS
Plastic analysis of prismatic compression members in buildings is permitted if
does not exceed 800 and Fu65 ksi (448 MPa). For axially loaded
members with b/tr, the maximum load Pu, ksi (MPa6.894ksi), may be
computed from
(9.7)whereAggross cross-sectional area of the member
Fcr0.658Fyfor2.25
0.877Fy/for 2.25
(Kl/r)^2 (Fy/ 286,220)
The AISC specification for LRFD presents formulas for designing members
with slender elements.
ALLOWABLE-STRESS DESIGN FOR BUILDING BEAMS
The maximum fiber stress in bending for laterally supported beams and girders
isFb0.66Fyif they are compact, except for hybrid girders and members with
yield points exceeding 65 ksi (448.1 MPa). Fb0.60Fyfor noncompact
Pu0.85AgFcrFy (l/r)2.0
2.0
2.0
2.10
1.0
1.0
1.0
1.2
0.7
0.80
0.5
(a) (b) (c) (d) (e) (f )0.65
Recommended design value when
ideal conditions are approximatedEnd conditionRotation fixed and translation fixedRotation fixed and translation free
Rotation free and translation freeRotation free and translation fixedTheoreticalK valueBuckled shape of column
is shown by dashed lineFIGURE 9.1 Values of effective-length factor Kfor columns.