Modern Control Engineering

(Chris Devlin) #1
348 Chapter 6 / Control Systems Analysis and Design by the Root-Locus Method

The breakaway and break-in points are determined from

as follows:

Notice that both points are on root loci. Therefore, they are actual breakaway or break-in
points. At point s=–0.634,the value of Kis

Similarly, at s=–2.366,

(Because point s=–0.634lies between two poles, it is a breakaway point, and because point
s=–2.366lies between two zeros, it is a break-in point.)

K=-

(–2.366)(–1.366)

(–0.366)(0.634)

= 14

K=-

(-0.634)(0.366)

(1.366)(2.366)

=0.0718

s=-0.634, s=-2.366


= 0

=-

4(s+0.634)(s+2.366)
C(s+2)(s+3)D^2

dK
ds

=-

(2s+1)(s+2)(s+3)-s(s+1)(2s+5)
C(s+2)(s+3)D^2

(a) (b)

R(s) C(s)

jv

s

K= 0.0718

K= 14


  • 3–2–1 01


j 1

j 2


  • j 1

  • j 2


+ K(s+ 2) s(ss++^3 1)





Figure 6–64
(a) Control system; (b) root-locus plot.

Openmirrors.com