TABLE 13.3a
Characteristics of All-Aluminum-Conductors (AAC)
Cross-Section AreaDiameterApprox. Current-Carrying CapacityResistance (mV=km)60 Hz Reactances(Dm¼
1m)DCAC (60 Hz)GMRXLXCCode(mm2 )kcmil or AWGStranding(mm)Layers(Amperes)25
8 C258 C508 C758 C(mm)(V=km)(MV=km)Coreopsis806.215916136.934138036.539.542.946.314.260.3200.190Glaldiolus765.815116135.994134038.441.344.948.513.900.3220.192Carnation725.414326135.034130040.543.347.150.913.530.3240.193Columbine865.313526134.044125042.945.649.653.613.140.3270.196Narcissus644.512726133.024120045.548.152.556.712.740.3290.194Hawthorn604.111926131.954116048.751.055.660.312.340.3310.197Marigold564.211136130.894111052.154.359.364.311.920.3340.199Larkspur52410346129.774106056.158.263.669.011.490.3370.201Bluebell524.110343729.713106056.158.263.568.911.400.3370.201Goldenrod483.79556128.64101060.862.768.674.411.030.3400.203Magnolia483.69543728.553101060.862.768.674.510.970.3400.203Crocus443.68756127.38495066.368.174.580.910.580.3430.205Anemone443.58753727.36395066.368.174.580.910.490.3440.205Lilac403.17966126.11490073.074.681.788.610.090.3470.207Arbutus402.97953726.06390073.074.681.788.610.000.3470.207Nasturtium362.57156124.76484081.282.690.598.49.570.3510.209Violet362.87163724.74384081.182.590.498.39.480.3510.209Orchid322.26363723.32378091.392.6101.5110.48.960.3560.212Mistletoe281.85563721.793730104.4105.5115.8126.08.380.3610.215Dahlia281.85561921.722730104.4105.5115.8125.98.230.3620.216Syringa241.54773720.193670121.8122.7134.7146.77.740.3670.219Cosmos241.94771920.142670121.6122.6134.5146.57.620.3680.219Canna201.63981918.362600145.9146.7161.1175.56.950.3750.224Tulip170.63371916.922530172.5173.2190.1207.16.400.3810.228Laurel135.22671915.062460217.6218.1239.6261.05.700.3900.233Daisy135.3267714.881460217.5218239.4260.85.390.3940.233Oxlip107.3212 or (4=0)713.261340274.3274.7301.7328.84.820.4020.239Phlox85168 or (3=0)711.791300346.4346.4380.6414.74.270.4110.245Aster67.5133 or (2=0)710.521270436.1439.5479.4522.53.810.400.25Poppy53.5106 or (1=0)79.351230550550.2604.5658.83.380.4290.256Pansy42.4#1 AWG78.331200694.2694.2763.2831.63.020.4380.261Iris33.6#2 AWG77.421180874.5874.5960.81047.92.680.4460.267Rose21.1#3 AWG75.8911601391.51391.51528.91666.32.130.4640.278Peachbell13.3#4 AWG74.6711402214.42214.42443.226521.710.4810.289Current capacity evaluated at 758 C conductor temperature, 258 C air temperature, wind speed of 1.4 mi=h, and frequency of 60 Hz.Sources:Transmission Line Reference Book 345 kV and Above, 2nd ed., Electric Power Research Institute, Palo Alto, California, 1987. With permission.Glover, J.D. and Sarma, M.S.,Power System Analysis and Design,3rded.,Brooks=Cole, 2002. With permission.