Handbook of Civil Engineering Calculations

(singke) #1
Study of the above computations shows that the rivet pattern is satisfactory.


  1. Design the splice plates
    To the left of the centerline, each splice plate bears against the left half of the rivet. There-
    fore, the entire load has been transmitted to the splice plates at cc, which is the critical
    section. Thus the tension in splice plate = ^(99,00O) = 49,500 Ib (220,176.0 N); plate
    thickness required = 49,500/[22,000(7)] = 0.321 in (8.153 mm). Make the splice plates
    10 x 3/ 8 in (254.0 x 9.53 mm).


DESIGN OF A PIPE JOINT


A steel pipe 5 ft 6 in (1676.4 mm) in diameter must withstand a fluid pressure of
225 lb/in^2 (1551.4 kPa). Design the pipe and the longitudinal lap splice, using^3 / 4 -in
(19.05-mm) rivets.

Calculation Procedure:


  1. Evaluate the hoop tension in the pipe
    Let L denote the length (Fig. 57) of the repeating group of rivets. In this case, this equals
    the rivet pitch. In Fig. 57, let T denote the hoop tension, in pounds (newtons), in the dis-
    tance L. Evaluate the tension, using T = pDLI2, where/? = internal pressure, lb/in^2 (kPa);
    D = inside diameter of pipe, in (mm); L = length considered, in (mm). Thus, T =
    225(66)Z/2 = 7425L


FIGURE 56

Main plate
Splice plate
Free download pdf