Handbook of Civil Engineering Calculations

(singke) #1
Calculation Procedure:


  1. Compute the properties of the section
    The tables in the AISC Manual are helpful in calculating the moment of inertia. Thus Af
    = 15 in^2 (96.8 cm^2 ); Aw = 24.75 in^2 (159.687 cm^2 ); / = 42,400 in^4 (176.481 dm^4 ); S =
    1256 in^3 (20,585.8 cm^3 ).
    For the T section comprising the flange and one-sixth the web, A = 15 + 4.13 = 19.13
    in^2 (123.427 cm^2 ); then /= (1/12)(0.75)(20)^3 = 500 in^4 (2081.1 dm^4 ); r = (500/19.13)^05 =
    5.11 in (129.794 mm); LYr = 18(12)75.11 =42.3.

  2. Ascertain if the member satisfies the AISC Specification
    Let h denote the clear distance between flanges, in (cm). Then: flange, ^(2O)A).75 = 13.3
    < 16—this is acceptable; web, hltw = 66/0.375 = 176 < 320—this is acceptable.

  3. Compute the allowable bending stress
    Use /! = 22,000 - 0.679(1 Vr)^2 /Q, or fi = 22,000 - 0.679(42.3)^2 = 20,800 lb/in^2
    (143,416.0 kPa); / 2 = 12,000,000/(L'^) = 12,000,000(15)/[18(12)(67.5)] = 12,300
    lb/in^2 (84,808.5 kPa). Therefore, use 20,800 lb/in^2 (143,416.0 kPa) because it is the larger
    of the two stresses.

  4. Reduce the allowable bending stress In accordance with the
    AISC Specification
    Using the equation given in the Manual yields / 3 = 20,800(1 - 0.005(24.75/15)[176 -
    24,000/(20,80O)
    0



  • 5
    ]} = 20,600 lb/in
    2
    (142,037.0 kPa).



  1. Determine the allowable bending moment
    Use Af =/ 35 = 20.6(1256)712 = 2156 ft-kips (2923.5 kN-m).


ANALYSIS OFA RIVETED PLATE GIRDER


A plate girder is composed of one web plate 48 x^3 / 8 in (1219.2 x 9.53 mm); four flange
angles 6 x 4 x % in (152.4 x 101.6 x 19.05 mm); two cover plates 14 x y 2 in (355.6 x 12.7
mm). The flange angles are set 48.5 in (1231.90 mm) back to back with their 6-in (152.4-
mm) legs outstanding; they are connected to the web plate by 7s-in (22.2-mm) rivets. If
the member has continuous lateral support, what bending moment may be applied? What
spacing of flange-to-web rivets is required in a panel where the vertical shear is 180 kips
(800.6 kN)?


Calculation Procedure:


  1. Obtain the properties of the angles from the AISC Manual
    Record the angle dimensions as shown in Fig. 7.

  2. Check the cover plates for compliance with the
    AISC Specification
    The cover plates are found to comply with the pertinent sections of the Specification.

  3. Compute the gross flange area and rivet-hole area
    Ascertain whether the Specification requires a reduction in the flange area. Therefore
    gross flange area = 2(6.94) + 7.0 = 20.88 in^2 (134.718 cm^2 ); area of rivet holes =
    2C/2)(1)4(^3 /4)(1) = 4.00 in^2 (25.808 cm^2 ); allowable area of holes = 0.15(20.88) = 3.13.

Free download pdf