Handbook of Civil Engineering Calculations

(singke) #1

Calculation Procedure:



  1. Assume that d = 7.5 in (19O.5 mm), and classify the column
    Thus, LId= 144/7.5 = 19.2 and K= 0.64(1,760,000/140O)^05 = 22.7. This is an intermedi-
    ate column if the assumed dimension is correct.

  2. Compute the required area and select a section
    For an intermediate column, the stress/= 1400(1 -^1 X 3 (19.2/22.7)4] = 1160 lb/in^2 (7998.2
    kPa). Then^ = PIf= 98,000/1160 = 84.5 in^2 (545.19 cm^2 ).
    Study of the required area shows that an 8 12 in (203.2 304.8 mm) column having
    an area of 86.3 in^2 (556.81 cm^2 ) should be used.


INVESTIGATION OFA SPACED COLUMN


The wooden column in Fig. 2 is composed of three 3 8 in (76.2 203.2 mm) sections.
Determine the capacity of the member if/c = 1400 lb/in
2
(9653 kPa) and E = 1,760,000
lb/in
2
(12,135.2 MPa).


Calculation Procedure:



  1. Record the properties
    of the elemental section
    In analyzing a spaced column, it is necessary to as-
    sess both the aggregate strength of the elements and
    the strength of the built-up section. The end spacer
    blocks exert a restraining effect on the elements and
    thereby enhance their capacity. This effect is taken
    into account by multiplying the modulus of elastici-
    ty by a. fixity factor F.
    The area of the column A = 19.7 in
    2
    (127.10
    cm
    2
    ) when the dressed sizes are used. Also, LId =
    114/2.625 = 43.4; F = 2.5; K = 0.64(2.5 x
    1,760,000/140O)
    05
    = 35.9. Therefore, this is a long
    column.

  2. Calculate the aggregate strength
    of the elements
    Thus,/= Q214EI(LId)
    2
    for a long column, or/ =
    0.274(2.5)(l,760,000)/(43.4)^2 = 640 lb/in^2 (4412.8
    kPa). P = 3(19.7)(640) = 37,800 Ib (168,134.4 N).

  3. Repeat the foregoing steps FIGURE 2 Spaced col-
    for the built-up member umn.
    Thus, LId= 114/7.5 x 15.2; K= 22.7; therefore, this
    is an intermediate column. Then / = 1400(1 -
    '/3(15.2/22J)^4 ] = 1306 lb/in^2 (9004.9 kPa) > 640
    lb/in^2 (4412.8 kPa).
    The column capacity is therefore limited by the elements and P = 37,800 Ib (168,134.4
    N).