Handbook of Civil Engineering Calculations

(singke) #1
(a) SpI it-ring connection
FIGURE 8

The Specification requires a minimum edge distance of 2% in (69.85 mm). The edge
distance in the present instance is 33 A in (95.25 mm).


  1. Calculate the net area of member A
    Apply the dimensions of the groove, which are recorded in the Specification. Referring to
    Fig. Sb, gross area = 27.19 in^2 (175.430 cm^2 ). The projected area of the groove and bolt
    hole = 4.5(1.00) + 0.813(2.625) = 6.63 in^2 (42.777 cm^2 ). The net area = 27.19 - 6.63 =
    20.56 in^2 (132.7 cm^2 ).

  2. Calculate the stress at the net section; compare
    with the allowable stress
    The stress/= load/net area = 26,000/20.56 = 1260 lb/in^2 (8688 kPa). From the Specifica-
    tion, the allowable stress is/allow = (%)(1700) = 1488 lb/in^2 (10,260 kPa). Also from the
    Specification, f^w = 1650 lb/in^2 (11,377 kPa). The joint is therefore satisfactory in all re-
    spects.

  3. Establish the connector spacing
    Using the Specification, apply the recorded values without reduction because the connec-
    tors are stressed almost to capacity. Thus, a = 1 in (177.8 mm) and b = 9 in (228.6 mm).


(b) Deduction for net section
of member A

Projection
of bolt
hole

•Projection-
of groove