FIGURE 12. Pump performance curve (A If a Laval Pumps, Inc.)
TDH was calculated above to be 26 lb/in^2 (179.1 kPa); Sf= (25 gal/100 revs)(0.757) + 3 =
21.925.
- Determine the pump horsepower
The viscosity of a sewage sludge is dependent upon the percent solids and may be found
using Table 3.
Using Table 3, a 5 percent solids sludge has a viscosity of 1,050 cp. Therefore:
Nf= 2.2 Vl,050 cp = 22.36
Using the values outlined above, the motor horsepower is calculated:
HP 175 rpm r (175 rpm)(21.925) (25)(22.36) 1
- -iir K
043
*
25 gai/io
°
revs)(26 psi)+
id*—-
+
^u
2
I
= 1.3hp(0.97kW)
The resulting horsepower of 1.3 hp (0.97 kW) is at best an informed estimate of the horse-
power which will be absorbed at the pump shaft during pumping. It includes no service
factor or margin for error, neither does it allow for inefficiency in power transmission sys-
tems.