3.8. Beyond Standard Logic: Applications
Precision Timers “555”
This device is a precision timer that may be configured for a variety of applications. The most
common use of the NE 555 is an application to generate square waves that may be used as a clock
signal in digital design. In order for NE 555 to generate the clock signal, it may be configured as
shown below:
Example
Given the component values in the introduction of NE 555 (above), draw the clock (square wave)
signal generated and determine the period, frequency and duty cycle for the signal.Solution: