SMRP BoK Review Workbook

(mmpvcentral) #1

Everyone in the world has this PM inspection for hydraulic systems. Inspect hydraulic hoses for wear and hose fittings for leaks.


▪ If we have A, B, C, D options is it more repeatable?
▪ Will the 20-year veteran and the 1-year veteran return the same information?
▪ Will the 5-year veteran return the same information twice in a row?

D is emergent work today, B&C are future work... later this week, next week,
order hoses, have them made up and ready for install.


For D, add a note to fix it. It cannot be charged to the PM.


Add 4 photographs. 1 of each one.


Avoid words like Test, Inspect, Check


Summary:


▪ The multiple-choice selections with detailed, real world descriptions
makes the inspection repeatable.

D... if you can fix it in less than 15 minutes, fix it and charge it to the PM

Be consistent – is coupling a component or a part. Is it part of the driver? A
separate component?

▪ The opportunity for the inspector to write in the # of occurrences
makes it quantitative.