- If not within the specification, perform the operating inspection. (See Operating Inspection .)
ATF temperature: 20 80 °C {68 176 °F}
Terminals Solenoid valve
Resistance (ohm)
(Reference value)
EJ Shift solenoid A 2.74.4
FJ Shift solenoid B 2.74.4
GJ TCC solenoid 12.116.0
HJ Shift solenoid C 2.74.4
IJ Shift solenoid F 2.74.4
KJ
Pressure
control solenoid
12.316.3
- Connect the solenoid valve connector.
- Install the insulator.
Tightening torque
o 8 11 N·m {82112 kgf·cm, 7297 in·lbf}
- Install the catalytic converter. (See EXHAUST SYSTEM REMOVAL/INSTALLATION .)
- Connect the negative battery cable.
- Install the battery cover.
- Install the engine cover. (See ENGINE COVER REMOVAL/INSTALLATION .)
Operating Inspection
- Remove the engine cover. (See ENGINE COVER REMOVAL/INSTALLATION .)
- Remove the battery cover.
- Disconnect the negative battery cable.
- Remove the catalytic converter. (See EXHAUST SYSTEM REMOVAL/INSTALLATION .)
- Remove the insulator.
(w) RX-8 Transmission (Manual & Auto)