Hardware Manual PCD 1 / PCD 2 Series│Document 26 / 737│Edition EN 15│2008-07-22
Saia-Burgess Controls AG
Interrupt inputs
CPUs and expansion housings
3
Interrupt
input
XOB called in case of a
positive edge
Input where the relevant XOB
is not programmed
IN0 XOB 20 I 8100
IN1 XOB 21 I 8101
IN2 XOB 22 I 8102
IN3 XOB 23 I 8103
4 k 7
10 k
4 k 7
IN2
IN1
L
IN3
0 1 2 3 4 5 6 7 8
IN0
9
PGND
Input signals (source operation): PGND
H = 15.. 30 V
L = -30.. + 5 V or no connected
Input signals (sink operation):
H = 15 .. 30 V or no connected
L = -30.. + 5 V
source operation
(for sink operation
L at +24 V)
3.3 nF
μC
CF 5407
OUT4
OUT5
i
Outputs OUT4 and OUT5 can be used as “normal”, short-circuit-proof transistor
outputs with addresses O 8104 and O 8105, and each loaded up to 0.5 A.
Where the OUT4/OUT5 outputs are used, the + connection (terminal 6) must have a
+24 V supply.