- When setting TIME, remember that this load step option specifies time at the end of the load step. The
default value is 1.0 for the first load step. For subsequent load steps, the default is 1.0 plus the time specified
for the previous load step. Although time has no physical meaning in a static analysis (except in the case
of creep, viscoplasticity, or other rate-dependent material behavior), it is used as a convenient way of re-
ferring to load steps and substeps (see Loading in the Basic Analysis Guide).
2.2.2.3. The Transient Tab
The Transient tab contains transient analysis controls; it is available only if you choose a transient
analysis and remains grayed out when you choose a static analysis. For these reasons, it is not described
here.
2.2.2.4. Using the Sol'n Options Tab
You can use the Sol'n Options tab to set the options listed in Table 2.2: Sol'n Options Tab Options (p. 12).
For specific information about using the Solution Controls dialog box to set these options, access the
dialog box, select the Sol'n Options tab, and click the Help button.
Table 2.2: Sol'n Options Tab Options
For more information about this option, see the following
section(s) in the Basic Analysis Guide:
Option
Specify equation solver [EQSLV] • Selecting a Solver
Specify parameters for multiframe
restart [RESCONTROL]
- Multiframe Restart
Special considerations for setting these options in a static analysis include:
- When setting EQSLV, specify one of these solvers:
- Program chosen solver (ANSYS selects a solver for you, based on the physics of the problem)
- Sparse direct solver (default for linear and nonlinear, static and full transient analyses)
- Preconditioned Conjugate Gradient (PCG) solver (recommended for large size models, bulky structures)
- Iterative solver (auto-select; for linear static/full transient structural or steady-state thermal analyses
only; recommended)
2.2.2.5. Using the Nonlinear Tab
You can use the Nonlinear tab to set the options listed in Table 2.3: Nonlinear Tab Options (p. 12). For
specific information about using the Solution Controls dialog box to set these options, access the dialog
box, select the Nonlinear tab, and click the Help button.
Table 2.3: Nonlinear Tab Options
For more information about this option, see the following
section(s) in the Structural Analysis Guide:
Option
Activate line search [LNSRCH] • Line Search Option (p. 247)
- Line Search (p. 270)
Release 15.0 - © SAS IP, Inc. All rights reserved. - Contains proprietary and confidential information
Structural Static Analysis