Food Biochemistry and Food Processing (2 edition)

(Wang) #1

BLBS102-c45 BLBS102-Simpson March 21, 2012 14:38 Trim: 276mm X 219mm Printer Name: Yet to Come


45 Biosensors for Sensitive Detection of Agricultural Contaminants, Pathogens and Food-Borne Toxins 875

FAO 2004. Marine biotoxins: FAO food and nutrition. 2004. Paper
80.
Flampouri K et al. 2010. Development and validation of a cellular
biosensor detecting pesticide residues in tomatoes.Talanta80(5):
1799–1804.
Fonfr ́ıa ES et al. 2007. Paralytic shellfish poisoning detection by sur-
face plasmon resonance-based biosensors in shellfish matrixes.
Anal Chem79(16): 6303–6311.
Fusetani N, Kern W. 2009. Marine toxins: an overview.Prog Mol
Subcell Biol46: 1–44.
Gao Z et al. 2009. Immunochip for the detection of five kinds of
chemicals: atrazine, nonylphenol, 17-beta estradiol, paraverine
and chloramphenicol.Biosens Bioelectron24(5): 1445–1450.
Giraudi G, Baggiani C. 1994. Immunochemical methods for envi-
ronmental monitoring.Nucl Med Biol21(3): 557–572.
Gomez AH et al. 2005. Impulse response of pear fruit and its rela- ́
tion to Magness-Taylor firmness during storage.Postharvest Biol
Technol35(2): 209–215.
Gouzy MF et al. 2009. A SPR-based immunosensor for the detection
of isoproturon.Biosens Bioelectron24(6): 1563–1568.
Hartl M, Humpf HU. 1999. Simultaneous determination of fumon-
isin B1 and hydrolyzed fumonisin B1 in corn products by liq-
uid chromatography/electrospray ionization mass spectrometry.
J Agric Food Chem47(12): 5078–5083.
Hearty S et al. 2006. Production, characterisation and potential ap-
plication of a novel monoclonal antibody for rapid identification
of virulentListeria monocytogenes.J Microbiol Methods66(2):
294–312.
Herranz S et al. 2008. Preparation of antibodies and development of
a sensitive immunoassay with fluorescence detection for triazine
herbicides.Anal Bioanal Chem391(5): 1801–1812.
Holliger P et al. 1993. “Diabodies”: small bivalent and bispecific
antibody fragments.Proc Natl Acad Sci USA90(14): 6444–6448.
Homola J. 2003. Present and future of surface plasmon resonance
biosensors.Anal Bioanal Chem377(3): 528–539.
Hudson PJ, Souriau C. 2003. Engineered antibodies.Nat Med9(1):
129–134.
Jawaheer S et al. 2003. Development of a common biosensor format
for an enzyme-based biosensor array to monitor fruit quality.
Biosens Bioelectron18(12): 1429–1437.
Karlsson R. 2004. SPR for molecular interaction analysis: a review
of emerging application areas.J Mol Recognit17(3): 151–161.
Keay RW, McNeil CJ. 1998. Separation-free electrochemical im-
munosensor for rapid determination of atrazine.Biosens Bioelec-
tron13(9): 963–970.
Keller NP et al. 2005. Fungal secondary metabolism – from bio-
chemistry to genomics.Nat Rev Microbiol3(12): 937–947.
Kim SJ et al. 2007. Novel miniature SPR immunosensor equipped
with all-in-one multi-microchannel sensor chip for detecting low-
molecular-weight analytes.Biosens Bioelectron23(5): 701–707.
Kohler G, Milstein C. 1975. Continuous cultures of fused cells ̈
secreting antibody of predefined specificity. Nature (Lond)
256(5517): 495–497.
Koo OK et al. 2009. Targeted capture of pathogenic bacteria using
a mammalian cell receptor coupled with dielectrophoresis on a
biochip.Anal Chem81(8): 3094–3101.
Kortt AA et al. 1997. Single-chain Fv fragments of anti-
neuraminidase antibody NC10 containing five- and ten-residue
linkers form dimers and with zero-residue linker a trimer.Protein
Eng10(4): 423–433.

Koubov ́a V et al. 2001. Detection of foodbourne pathogens us-
ing surface plasmon resonance biosensors.Sensors Actuators
74(1–3): 100–105.
Kriz K et al. 2002. Amperometric determination of L-lactate based
on entrapment of lactate oxidase on a transducer surface with
a semi-permeable membrane using a SIRE technology-based
biosensor. Application: tomato paste and baby food.J Agric Food
Chem50(12): 3419–3424.
Kroger S et al. 2002. Biosensors for marine pollution research, ̈
monitoring and control.Mar Pollut Bull45(1–12): 24–34.
Lacy A et al. 2006. Rapid analysis of coumarins using surface
plasmon resonance.JAOACInt89(3): 884–892.
Leenaars M, Hendriksen CFM. 2005. Critical steps in the produc-
tion of polyclonal and monoclonal antibodies: evaluation and
recommendations.ILAR J46(3): 269–279.
Leonard P et al. 2004. A generic approach for the detection of
wholeListeria monocytogenescells in contaminated samples us-
ing surface plasmon resonance.Biosensors Bioelectron19(10):
1331–1335.
Leonard P et al. 2005. Development of a surface plasmon resonance-
based immunoassay forListeria monocytogenes.J Food Prot
68(4): 728–735.
Liao WC, Ho JA. 2009. Attomole DNA electrochemical sensor for
the detection ofEscherichia coliO157:H7.Anal Chem81(7):
2470–2476.
Liebana S et al. 2009. Rapid detection of ́ Salmonellain milk by
electrochemical magneto-immunosensing.Biosens Bioelectron
25(2): 510–513.
Llamas NM et al. 2007. Development of a novel immunobiosensor
method for the rapid detection of okadaic acid contamination in
shellfish extracts.Anal Bioanal Chem389(2): 581–587.
Luong JHT et al. 1995. Enzyme reactions in the presence of cy-
clodextrins: biosensors and enzyme assays.Trends Biotechnol
13(11): 457–463.
MacLean DD et al. 2006. Postharvest variation in apple (Malus
x domestica Borkh.) flavonoids following harvest, storage, and
1-MCP treatment.J Agric Food Chem54(3): 870–878.
March C et al. 2009. A piezoelectric immunosensor for the de-
termination of pesticide residues and metabolites in fruit juices.
Talanta78(3): 827–833.
Markey F. 2000. Principles of surface plasmon resonance. In: K
Nagata, KH Handa (eds.)Real-Time Analysis of Biomolecular
Interactions. Springer, Tokyo, pp. 13–22.
McGuinness BT et al. 1996. Phage diabody repertoires for selection
of large numbers of bispecific antibody fragments.Nat Biotechnol
14(9): 1149–1154.
Minunni M, Mascini M. 1993. Detection of pesticides in drinking
water using real-time biospecific interaction analysis (BIA).Anal
Lett26(7): 1441–1460.
Mitchum B et al. 1996. Methods for determining quality of fresh
commodities.Perishables Handle Newsletters85: 1–5.
Moran E et al. 2002. Methods for generation of monoclonal anti-
bodies to the very small drug hapten, 5-benzimidazolecarboxylic
acid.J Immunol Methods271(1–2): 65–75.
Muhammad-Tahir Z, Alocilja EC. 2004. A disposable biosensor for
pathogen detection in fresh produce samples.Biosyst Eng88(2):
145–151.
Mullett W et al. 1998. Immunoassay of fumonisins by a sur-
face plasmon resonance biosensor.Anal Biochem258(2): 161–
157.
Free download pdf