(a) (b) (c)
Figure 14: Three different implant models. (a) Mesh size 1.0. (b) Size 1.5. (c) Size 2.0.
CLOAD: 10000
6DOF fixed
Figure 15: Boundary and load condition for evaluation.
Size: 1.0 Size: 1.5 Size : 2.0
Max. displacement Max. displacement
Max. displacement
Contour plot
Displacement (Z)
Global system
5.800E + 00
3.734E + 00
1.668E + 00
−3.981E − 01
−2.464E + 00
−4.530E + 00
−6.596E + 00
−8.662E + 00
−1.073E + 01
−1.279E + 01
Contour plot
Displacement (Z)
Global system
Contour plot
Displacement (Z)
Global system
5.677E + 00
3.676E + 00
1.674E + 00
−3.275E − 01
−2.329E + 00
−4.331E + 00
−6.332E + 00
−8.334E + 00
−1.034E + 01
−1.234E + 01
5.106E + 00
3.260E + 00
1.415E + 00
−4.309E − 01
−2.277E + 00
−4.122E + 00
−5.968E + 00
−7.813E + 00
−9.659E + 00
−1.150E + 01
No result No result No result
(z-axis):5.800mm (z-axis):5.677mm
(z-axis):5.106mm
X
Z Y
X
Z Y
X
Z Y
Figure 16: Analysis results.
industries by providing the developed human spinal infor-
mation database, model, and virtual simulator to relevant
researchers.
Conflict of Interests
The authors declare that there is no conflict of interests
regarding the publication of this paper.
Acknowledgment
This work was supported by 2014 National Agenda Project
(NAP) funded by Korea Research Council of Fundamental
Science & Technology (NAP-09-2).
References
[1] N. Howard and E. Cambria, “Intention awareness: improving
upon situation awareness in human-centric environments,”
Human-Centric Computing and Information Sciences,vol.3,no.
9, pp. 2–17, 2013.
[2]P.Gargiulo,T.Helgason,P.Ingvarsson,W.Mayr,H.Kern,
and U. Carraro, “Medical image analysis and 3-d modeling
to quantify changes and functional restoration in denervated
muscle undergoing electrical stimulation treatment,”Human-
Centric Computing and Information Sciences,vol.2,no.10,pp.
2–11, 2012.
[3] M. Brahami, B. Atmani, and N. Matta, “Dynamic knowledge
mapping guided by data mining: application on Healthcare,”
Journal of Information Processing Systems,vol.9,no.1,pp.1–30,
2013.