Handbook of Hygiene Control in the Food Industry

(singke) #1
37.9 References and furtherreading

AGRANOVSKI V, RISTOVSKIZ, HARGREAVESM, BLACKALL,P JandMORAWSKL(2003a),
Real-timemeasurementof bacterialaerosolswiththe UVAPS:performance evaluation',AerosolSci, 34 , 301±317. AGRANOVSKI V, RISTOVSKIZ, HARGREAVESM, BLACKALL P JandMORAWSKL(2003b), Performanceevaluationof the UVAPS:influenceof physiologicalage of airborne
bacteriaand bacterialstress',AerosolSci, 34 , 1711±1727.
ALVAREZA J, BUTTNERM PandSTETZENBACH L D(1995),PCRfor bioaerosolmonitoring: sensitivityand environmentalinterference',ApplEnvironMicrobiol, 61 , 3639± 3644. AMBROISED, GREFF-MIRGUETG, GO»RNERP, FABRIE¬S J F and HARTEMANNP(1999), Measurement of indoor viable airborne bacteria with different bioaerosol
samplers',J AerosolSci, 30 , Suppl.1, S699±S700.
ANDERSENA A(1958),Newsamplerfor the collection,sizingand enumerationof viable airborneparticles',J Bacteriol, 76 , 471±484. BOERE DandBEUMERR R(1999),Methodologyfor detectionand typingof foodborne
microorganisms',Int J FoodMicrobiol, 50 , 119±130.
BOURDILLONR B, LIDWELLO MandTHOMAS J C(1941),A slit samplerfor collectingand countingairbornebacteria',J Hyg, 14 , 197±224. BRADYP(1999),AutoTrack.The nextgenerationin monitoring',Brewer, 85 , 130±133.
BROSSEAUL M, VESLEYD, RICEN, GOODELL K, NELLISM andHARISTONP(2000),
Differencesin detectedfluorescenceamongseveralbacteralspeciesmeasured witha direct-readingparticlesizerand fluorescencedetector',AerosolSci Technol, 32 , 545±558. BROWNA D(1953),Thesurvivalof airbornemicroorganisms,III. Effectsof temperature',
AustJ BiolSci, 7 , 444±451.
CANNONR Y(1970),Typesand populationof microorganismsin the air of fluidmilk plants',J MilkFoodTechnol, 33 , 19±21. CLARKS, LACHVandLIDWELLO M(1981),Theperformanceof the BiotestRCS
centrifugalair sampler',J HospInf, 2 , 181±186.
COXC SandWATHESC M(1995),BioaerosolsHandbook, BocaRaton,CRCLewis
Publishers.
CUNDELLA M, BEANR, MASSIMOREL andMAIERC(1998), Statisticalanalysisof environmentalmonitoringdata:doesa worstcase timefor monitoringcleanrooms exist?',J PharmSci Technol, 52 , 326±330. DARKF AandCALLOWD S(1973),Theeffectof growthconditionson the survivalof
airborneE. coli', In HersJ F and WinklerK C,4th InternationalSymposiumon
Aerobiology, Utrecht,Oosthoek,97±99.
GOODLOWR JandLEONARD F A(1961),Viabilityand infectivityof microorganismsin experimentalairborneinfection',BacteriolRev, 25 , 182±187. GRIFFITHS W DandDECOSEMOG A L(1994),Theassessmentof bioaerosols:a critical
review',J AerosolSci, 25 , 1425±1458.
GRIFFITHS W DandSTEWARTI W(1999),Performanceof bioaerosolsamplersusedby the UK biotechnologyindustry',J AerosolSci, 30 , 1029±1040. GRIFFITHS W D, UPTONS LandMARKD(1993),Aninvestigationintothe collection
efficiencyand bioefficiencyof a numberof aerosolsamplers',J AerosolSci, 24 ,
S541±S542.
GRINSHPUNS S, WILLEKEK, ULEVICIUS V, JUOZAITIS A, TERZIEVAS, DONNELLYJ, STELMAG N


Improving air sampling 637
Free download pdf