Examples of Quality Control in Microbiology
Labscontinued
Clinical Microbiology Review 233
PARAMETER REQUIREMENT(S)
Media
Procedure manual
QC manual
Employee competency
Proficiency testing
Most exempt from retesting if purchased from manufacturer who follows CLSI guidelines. Obtain & retain
statement of QC. Retesting required for CHOC, selective media for Neisseria &Campylobacter.
Must be reviewed & signed annually by lab director. Changes must be approved & signed by lab director.
Obsolete procedures must be removed & retained for 2 years.
Record all QC results & document any corrective action. Forms should be reviewed & initialed by supervisor
monthly. Maintain for at least 2 years.
Verification on hiring & annually.
Test unknowns exactly as patient specimens. Must maintain an average score of 80%. Document
corrective action.