Quorum Sensing

(sharon) #1

  1. The signal intensity or peak area of each of the DSF family
    signals may vary in different LC-MS systems. We recommend
    to generate system-specific standard curves using the commer-
    cially available DSF and BDSF. Since IDSF and CDSF are not
    commercially available, the standard curves for these two signal
    molecules were not generated in the previous studies. Their
    relative concentrations can be roughly calculated using the
    standard curves for DSF or BDSF.


Acknowledgments


This protocol is adapted from [8, 9]. This work was supported by
the research grants from the National Natural Science Foundation
of China (No. 31471743 to HYW, No. 31301634 to ZL).

Fig. 4Typical mass spectrum of DSF and IDSF. (a) Ion chromatograms of DSF and IDSF in the culture
supernatant ofΔrpfCstrain (20 times concentrated). (b) MS analysis showing an exact molecular weight of
212.1700 Dalton for the detected DSF. (c) MS analysis of IDSF showing an exact molecular weight of
212.1704 Dalton for the detected IDSF


104 Lian Zhou et al.

Free download pdf