c(HSL) andc(HS) are the individual concentrations of HSL
and HS in the samples, whileS(HSL) hydrolyzed and non-
hydrolyzed and S(HS) non-hydrolyzed are the actually
measured sample concentrations as sum parameters for the
hydrolyzed and non-hydrolyzed samples.CRHSLandCRHS
are the cross-reactivity values calculated for each measured
plate by dividing the IC 50 values (equal toCin the equation
above) of the standard curve for HS by the IC 50 of the standard
curve for HSL forCRHSLor vice versa forCRHS(seeNote 10).
3.3 Acyl-HSL/HS
Extraction from Cell
Pellets [11]
- Add 3 ml of acidified ethyl acetate to a cell pellet and stir for
10 min at room temperature. - Evaporate the solvent under a continuous nitrogen stream (see
Note 11) at room temperature. - Reconstitute extract in 500μl EtOAc/ACN mixture and keep
it at 4C for further analysis.
3.4 Solid-Phase
Extraction (SPE)
of Supernatants [7]
- Weigh 25 mg of HMP in a glass vial for extraction of 2.5 ml cell
culture supernatant or HSL/HS standards, respectively. - Capture HMP at the edge of the vial using an external magnet
to discard wash solutions or culture medium after each step. - Condition HMP with 1 ml methanol and 1 ml purified water
for 2 min, respectively. - Add 2.5 ml of cell culture supernatant or HSL/HS standard
and incubate the mixture for 20 min at room temperature,
stirring occasionally. - Wash HMP with 2 ml of purified water.
- Elute HSL with a 2 ml solvent mixture of 3-propanol and
hexane (75:25% v/v) and transfer the eluant into a 2 ml tube. - Dry the eluants using a centrifugal vacuum concentrator or
evaporate solvent mixture under a low stream of nitrogen. - Redissolve extract in 250μlH 2 O/ACN mixture (90:10% v/v)
and keep it cooled for further analysis.
3.5 UHPLC-ESI-
QToF-MS Analysis
We routinely use a Waters Acquity UPLC, consisting of binary
solvent manager, tempered sample manager, tempered column
manager, and photo diode array detector, coupled to an electro-
spray ionization quadrupole time-of-flight mass spectrometer (ESI-
QToF-MS, Bruker Daltonik).
- Install reversed-phase C 18 column in the column manager and
set the temperature to 40C. - Install eluants A and B on the binary solvent manager and
purge all lines for 4 min with a flow rate of 8 ml/min. Equili-
brate the C 18 column starting with 100% eluant B and a flow
68 Michael Rothballer et al.