RNA Detection

(nextflipdebug2) #1
Capture Probe

CEs
LEs

Mix lysate with
all probes

Add hairpin
Set X

Add hairpin
Set A

Capture Stage

Amplification Stage

!!!

Adaptor

Target RNA

... ...
...
...

... ...
...
...
...

...

...
...

Fig. 4Schematic illustration of the direct RNA detection assay. For each target
RNA, the capture hybridization method is done with a series of oligonucleotide
probes (CEs and LEs), each of these probes containing a target-specific
sequence which is complementary to a different region of the target, and an
additional “tail” sequence that is independent of the target sequence but can
interact with either the solid support (CEs) or the adaptor (LEs). The CEs and LEs
sandwich the target RNA through target-specific hybridizations. The common CE
tail sequences hybridize to the capture probe conjugate on the surface of each
well in 96-well plate and capture the associated target RNA onto the plate. The
adaptors bind to the common LE tails and initiate the on-site 2D HCR after the
addition of hairpins. Figure adapted from [5] with permission from Elsevier

190 Yao Xu and Zhi Zheng