- Novell M, Parrilla M, Crespo G, Rius F, Andrade F (2012) Paper-based ion-selective
potentiometric sensors. Anal Chem 84:4695–4702 - Siva Rama Krishna V, Bhat N, Amrutur B, Chakrapani K, Sampath S (2011) Detection of
glycated hemoglobin using 3-aminophenylboronic acid modified graphene oxide. Life Sci-
ence Systems and Applications Workshop (LiSSA), 2011 IEEE/NIH, pp 1–4 - Liu Y, Banada P, Bhattacharya S, Bhunia A, Bashir R (2008) Electrical characterization of
DNA molecules in solution using impedance measurements. Appl Phys Lett 92:143902 - Yang M, Li S, Jiang D (2014) Review on optical fiber sensing technologies for industrical
applications at the NEL-FOST. In: EWSHM-7th European workshop on structural health
monitoring - Bhattacharya S, Jang J, Yang L, Akin D, Bashir R (2007) BioMEMS and nanotechnology‐
based approaches for rapid detection of biological entities. J Rapid Meth Automat Microbiol
15:1–32 - Seema Yardi A, Kant R, Boolchandani D, Bhattacharya S (2015) High efficiency coupling of
optical fibres with SU8 micro-droplet using laser welding process. Lasers in manufacturing
and materials processing, pp 1–17 - Binnig G, Quate C, Gerber C (1986) Atomic force microscope. Phys Rev Lett 56:930
- Lavrik N, Sepaniak M, Datskos P (2004) Cantilever transducers as a platform for chemical
and biological sensors. Rev Sci Instrum 75:2229–2253 - Tamayo J, Kosaka P, Kosaka J, San Paulo A, Calleja M (2013) Biosensors based on
nanomechanical systems. Chem Soc Rev 42:1287–1311 - Braun T, Ghatkesar M, Backmann N, Grange W, Boulanger P, Letellier L (2009) Quantita-
tive time-resolved measurement of membrane protein–ligand interactions using
microcantilever array sensors. Nat Nanotechnol 4:179–185 - Naik A, Hanay M, Hiebert W, Feng X, Roukes M (2009) Towards single-molecule
nanomechanical mass spectrometry. Nat Nanotechnol 4:445–450 - Kumar V, Boley W, Yang Y, Ekowaluyo H, Miller J, Chiu G (2011) Bifurcation-based mass
sensing using piezoelectrically-actuated microcantilevers. Appl Phys Lett 98:153510 - Gupta A, Akin D, Bashir R (2004) Single virus particle mass detection using microresonators
with nanoscale thickness. Appl Phys Lett 84:1976–1978 - Gupta A, Akin D, Bashir R (2004) Detection of bacterial cells and antibodies using surface
micromachined thin silicon cantilever resonators. J Vacuum Sci Technol B 22:2785–2791 - Davila A, Jang J, Gupta A, Walter T, Aronson A, Bashir R (2007) Microresonator mass
sensors for detection of Bacillus anthracis Sterne spores in air and water. Biosens Bioelectron
22:3028–3035
2 Microfluidics Overview 83