262 CHAPTER TEN
At points of maximum positive moments, Pis the smaller of P 1 andP 2 ,
computed from
(10.49)
(10.50)
whereAceffective concrete area, in^2 (mm^2 )
fc28-day compressive strength of concrete, ksi (MPa)
Astotal area of steel section, in^2 (mm^2 )
Fysteel yield strength, ksi (MPa)
The number of connectors required between points of maximum positive
moment and points of adjacent maximum negative moment should equal or
exceedN 2 , given by
(10.51)
At points of maximum negative moments, the force in the slab P 3 , is com-
puted from
(10.52)
whereAsrarea of longitudinal reinforcing within effective flange, in^2 (mm^2 );
andFyrreinforcing steel yield strength, ksi (MPa).
Ultimate Shear Strength of Connectors in Bridges
For channels,
(10.53)
wherehaverage channel-flange thickness, in (mm)
tchannel-web thickness, in (mm)
wchannel length, in (mm)
For welded studs (H/d4 in (101.6 mm),
(10.54)
ALLOWABLE-STRESS DESIGN FOR SHEAR IN BRIDGES
Based on the AASHTO specification for highway bridges, the allowable shear
stress, ksi (MPa), may be computed from
Fv (10.55)
Fy
3
C
Fy
3
Su0.4d^22 fcEc
Su17.4h
t
2
wfc
P 3 AsrFyr
N 2
PP 3
Su
P 2 0.85fcAc
P 1 AsFy