profile formwork
July 2019 B2B Purchase 55
Sharp Ply Calibrated Sheathing Sheet
C
alibrated sheathing sheet is
ultimate in plywood having
excellent physical and mechanical
properties. The rigid laminated surface
not only prevents moisture absorption
but also ensure excellent abrasion
resistance in aggressive conditions and
smooth finish to concrete formwork. It
has been designed to suit any and every
application needs of construction
industry where durability, versatility,
high bending strength, rigidity,
stability, accuracy and tolerance to
humidity parameters of performance
value are critical.
Tips for optimum utilisation of
shuttering plywood
Protect from weather: Store the
formworks and the loose formwork
panels against sun and rain.
Use standard tool: Film faced plywood
can be cut shaped and drilled using
standard wood working stools.
Seal edges and holes: Seal the
resulting raw edges and holes with
suitable water-resistant paint.
Oil panels before use: A suitable
approved release agent must be used
to ensure cleaner and easier striking
and also more re-users.
Back face fastening: To achieve the
best results, it is recommended that
the plywood should be fastened to the
formwork support members from the
back of the panel.
Avoid falling from height: Plywood
panels should be handled very
carefully when moving high above the
ground to prevent damages.
Clean after use: Plywood panels should be
cleaned carefully with water or damaging
the stream after use. Avoid damaging
the panels surface when cleaning the
concrete residues. n
Contact
Aditya Chowatia, Executive Director
Sharp Ply India Pvt Ltd
# 33, Middle School Road, V.V. Puram,
Bengaluru – 560004, Karnataka
Tele: +91-80-26600117
Email: [email protected]
http://www.sharpply.com
General Specifications
Items Value
Size 1,220 x 2,440 mm
Thickness 12 mm or 18mm
Wood Core Plantation Hardwood,
Grade A
Type WBP or Class 3
Film
Thickness
Phenolic 130 GSM,
Brown Colour
Density ≥ 650 kg/cu.m. or ≥ 630
kg/cu.m.
Technical Specification
No Properties Unit Values Testing Methods
1 Bonding Type Weather & Ball Proof-WBP (Class 3) EN 636:2003
2 Resin PF
3 Veneer Plantation Wood
4 Density Kg/m^3 ≥ 630 EN 323:1993
5 Overlay / Surface PSF > 130 GSM; Black Brown
6 Abrasive Test Rev 400 EN 438-2:2005
7 Thickness Tolerance mm +(0.2+0.03t)
-(0.4+0.03t)
EN 315:2000
(f )nominal thickness
8 Thickness Swelling % ≤8% EN 317:1993
9 Formaldehyde Emission mg/m2h E1 EN 717-2:1995
10 Bonding Strength N/mm^2 According to standard (>1.0) EN314-1:2004
11 Bending Strength
Parallel to the width of panel
Parallel to the length of panel
N/mm^2
>55(F55)
>30(F30)
EN 310:1993
12 Modulus of Elasticity
Parallel to the width of panel
Parallel to the length of panel
N/mm^2
>6000(E60)
>3000(E30)
EN 310:1993