- High-pressure segment low temperature super heater tube box
- High-pressure segment evaporator tube box
- Low-pressure segment super heater tube box
- High-pressure segment economizer 1&2
- Low-pressure segment evaporator tube box
- High-pressure segment economizer 3
- Low-pressure segment economizer tube box.
- Common Preheater
Dust will be collected in three hoppers. Collected dust will be conveyed through
closed drag chain conveyor to clinker silo.
1.6 Basic Plant Design Concept – Layout for AQC Boiler:
- AQC Boiler inlet gas tapping shall be designed with cooler design.
- Bothe Midtap-1&2 duct orientation shall be 180 Deg. with respect to cooler to
minimize the duct length and pressure drop. - AQC Boiler civil design to be integrated with Cement Cooler Building Design.
- Proper connectivity shall be considered between cooler operating and AQC
Boiler operating floor for ease of movement and maintenance. in line with down
comer duct.