Simulink Control Design™ - MathWorks

(Tuis.) #1
Change Analysis Point Type

To change the linear analysis point type for a signal, in the Analysis I/Os section, in the
Configuration drop-down list for the signal, select the analysis point type. For example,
if you want the signal to be a linearization output point, select Output Measurement.

Enable or Disable Analysis Points

To modify an existing linearization I/O set without removing analysis points, you can
disable one or more analysis points. To do so, in the Analysis I/Os section, under Active,
clear the corresponding check box.

When you linearize your model using the linearization I/O set, the software ignores any
disabled analysis points.

To enable a disabled analysis point, select the corresponding check box.

Edit Simulink Model Analysis Points


You can modify analysis points stored in your Simulink model using the Linear Analysis
Tool. To do so, on the Linear Analysis tab, in the Analysis I/Os drop-down list, select
Model I/Os, and then, in same drop-down list, select Edit Model I/Os.

2 Linearization

Free download pdf