Highway Engineering

(Nandana) #1

The fully factored flows entering, exiting and circulating within the round-
about are illustrated diagrammatically in Fig. 5.26 and graphically in Fig. 5.27.


The Design of Highway Intersections 129

ARM A ARM B ARM C
qAB qAC qBA qBC qCA qCB
Flow in veh/hr 150 350 200 200 650 250
Flow in pcu/hr (¥1.1) 165 385 220 220 715 275
Factored flow (¥1.125) 186 433 248 248 804 310
Factored entry flow (pcu/hr) 619 495 1114
Factored circulating flow (pcu/hr) 310 433 248

Table 5.4Entry flows


Figure 5.26Factored entry, circulating and exiting flows (pcu/hr).


Entry capacities


Given the circulating flows estimated above, the entry capacity for each of the
three arms can be computed as:


Arm A
QE= 1629 - 0.63Qc
= 1629 - (0.63 ¥310)
=1433 pcu/hr


Arm B
QE= 1549 - 0.614Qc
= 1549 - (0.614 ¥433)
=1283 pcu/hr

Free download pdf