Engineering Fundamentals: An Introduction to Engineering, 4th ed.c

(Steven Felgate) #1

170


(U.S. Customary version)


Designation


Depth (in.) Flange Width (in.) Area (in


2


)


W18 76 * 18.21 11.03 22.3
W16  57 16.43 7.12 16.8
W14  38 14.10 6.77 11.2
W8  31 8.00 7.95 9.1

y


y


x x


TABLE 7.2 Examples of Nominal Size versus Actual Size of Some Engineering Products (continued)
Dimension of Copper Tubing (Type M — for HVAC and domestic water applications)

Nominal Outside Inside Wall Flow Cross
Size (in.) Diameter (in.) Diameter (in.) Thickness (in.) Section (in^2 )

3/8 0.5 0.450 0.025 0.159
1/2 0.625 0.569 0.028 0.254
3/4 0.875 0.811 0.032 0.517
1 1.125 1.055 0.035 0.874
1 1.375 1.291 0.042 1.31
1 1.625 1.527 0.049 1.83
2 2.125 2.009 0.058 3.17
2 2.625 2.495 0.065 4.89
3 3.125 2.981 0.072 6.98
3 3.625 3.459 0.083 9.40
4 4.125 3.935 0.095 12.2
5 5.125 4.907 0.109 18.9

1


2


1


2


1


2


1


4


Examples of Standard Wide-Flange Beams (SI version)


Designation


Depth (mm) Flange Width (mm) Area (mm


2


)


W460 113 * 463 280 14,400
W410  85 417 181 10,800
W360  57 358 172 7,230
W200 46.1 203 203 5,890

y


y


x x




  • Nominal depth ( mm) and mass (kg) per one meter length.




  • Nominal depth (in.) and weight (lb) per one foot length.




Copyright 2010 Cengage Learning. All Rights Reserved. May not be copied, scanned, or duplicated, in whole or in part. Due to electronic rights, some third party content may be suppressed from the eBook and/or eChapter(s).