bottom and side-to-side, with extrane-
ous matter worked to the floor. This
prerinse is designed to remove heavy
soil deposits and to wet the surfaces.
- Apply an acid cleaning detergent
through a slurry or foam gun. Recom-
mended spray temperature is 55ºC or
lower. High-pressure output (for these
cleaning operations) is 25 to 70 kg/cm^2
and 7.5 to 12 L/min at the wand. - Within 20 minutes of the cleaning com-
pound application, apply a high-pres-
sure rinse with 50 to 55ºC water. - Remove, clean, and replace drain cov-
ers in the proper position after rinse-
down.
Processed Products, Offal,
and Storage Cooler
FREQUENCY Weekly. Processed meats,
offal, and hanging meat should be rotated so
that half of a section at a time can be cleaned
each week.
PROCEDURE
- Clean each section, when empty, with a
reliable floor cleaner. Apply slurry or
foam via high pressure. - Rinse thoroughly with 55ºC or lower
temperature water at high pressure
within 20 minutes of detergent applica-
tion. Do not splash water on hanging
meat in the section not being cleaned.
Work all debris to the floor from over-
head fixtures and walls. - Squeegee the floor where water has
accumulated to prevent it from freezing. - Remove, clean, and replace drain covers.
Fabricating or Further Processing
FREQUENCYDaily.
PROCEDURE
- Pick up all large pieces of lean, fat,
bones, and other extraneous matter,
and deposit them in a receptacle.
2. Cover all electrical connections with
plastic.
3. Prerinse all soiled surfaces with 55ºC
water. Start at the bone conveyor top
and work all extraneous matter down
to the floor. Avoid hosing motors, out-
lets, and electrical cables. - Following wash-down and subsequent
heavy soil removal, apply an alkaline
cleaner through a centralized or
portable high-pressure, low-volume sys-
tem, using 50 to 55ºC water. The system
should be effectively used to reach all
framework, table undersides, and other
difficult-to-reach areas. Allow 5 to 20
minutes of soak time prior to rinse-
down. Alternative equipment for clean-
ing compound application is a foam
unit. This unit rapidly applies the
cleaner but does not penetrate as well as
does high-pressure, low-volume equip-
ment and may be less effective in the
removal ofL. monocytogenes.
5. Rinse all equipment within 20 minutes
after cleaning compound application.
Using the same pattern as with pre-
rinse and cleaning compound applica-
tion, spray 50 to 55ºC water on one
side of equipment at a time.
6. Thoroughly inspect all equipment sur-
faces and conduct any necessary
touch-up.
7. Apply an organic sanitizer to all clean
equipment with a centralized or
portable sanitizing unit.
8. Remove, clean, and replace all drain
covers.
9. Apply white edible oil to surfaces sub-
ject to rust or corrosion. - Avoid contamination during mainte-
nance, as described previously.
If a bone shelter or hopper exists, it
should also be cleaned, as outlined in the
preceding steps. This operation should be
Meat and Poultry Plant Sanitation 317